Test Configuration
www.ti.com
5.2
Procedure
Follow these procedures when configuring the EVM for testing.
CAUTION
Many of the components on the TPS65708EVM-587 are susceptible to damage
by electrostatic discharge (ESD). Customers are advised to observe proper
ESD handling precautions when unpacking and handling the EVM, including
the use of a grounded wrist strap, bootstraps, or mats at an approved ESD
workstation. An electrostatic smock and safety glasses should also be worn.
1. Work at an ESD workstation. Make sure that any wrist straps, bootstraps, or mats are connected and
reference the user to earth ground before power is applied to the EVM. Electrostatic smock and safety
glasses should also be worn.
2. Connect a dc power supply between J17 and J19 on the TPS65708EVM. Note that the input voltage
should be in the range of 3.6 V to 6.0 V. Keep the wires from the input power supply to EVM as short
as possible and twisted.
3. Connect a dc voltmeter or oscilloscope to the output sense connections of the EVM: J2 for LDO1, J9
for LDO2, J15 for DCDC1, and J12 for DCDC2.
4. A load can be connected between the positive output of the dc-dc converters, LDOs, and GND.
5. To enable the converter, connect the shorting bar on JP10 (JP20) between EN and ON on the
TPS65708EVM.
6. The TPS65708EVM has the option to switch between power-save mode under light load conditions
and forced PWM mode by using jumper JP2.
7. Connect a signal generator (or any other source that provides a PWM output signal) to header J20 or
SMA connector J22. The amplitude of the PWM signal should conform to the low and high level
thresholds specified in the
. The PWM frequency can be up to 50 kHz.
The duty cycle of the PWM signal must be in the range of 5% to 100%.
8
TPS65708EVM
SLVU402 – October 2010
Copyright © 2010, Texas Instruments Incorporated