Texas Instruments TPS54339 Synchronous Step-Down DC/DC Converter Evaluation Module TPS54339EVM-056 TPS54339EVM-056 Datenbogen

Produktcode
TPS54339EVM-056
Seite von 17
Test Setup and Results
lists the R1 values for some common output voltages. For higher output voltages of 1.8 V or
above, a feedforward capacitor (C4) may be required to improve phase margin. Pads for this component
(C4) are provided on the printed-circuit board (PCB). Note that the resistor values given in
are
standard values and not the exact value calculated using
Table 3. Output Voltages
C8 + C9 + C10
Output
C4 (pF)
(1)
L1 (µH)
R1
R2
(µF)
Voltag
(k
Ω
)
(k
Ω
)
e (V)
Min
Typ
Max
Min
Typ
Max
Min
Max
1
6.81
22.1
5
150
220
1.5
2.2
4.7
22
68
1.05
8.25
22.1
5
150
220
1.5
2.2
4.7
22
68
1.2
12.7
22.1
5
100
1.5
2.2
4.7
22
68
1.5
21.5
22.1
5
68
1.5
2.2
4.7
22
68
1.8
30.1
22.1
5
22
2.2
3.3
4.7
22
68
2.5
49.9
22.1
5
22
2.2
3.3
4.7
22
68
3.3
73.2
22.1
5
22
2.2
3.3
4.7
22
68
5
124
22.1
5
22
3.3
4.7
22
68
6.5
165
22.1
5
22
3.3
4.7
22
68
(1)
Optional
3.2
Output Filter and Closed-Loop Response
The TPS54339 relies on the output filter characteristics to ensure stability of the control loop. The
recommended output filter components for common output voltages are given in
. It may be
possible for other output filter component values to provide acceptable closed-loop characteristics. R3 and
TP4 are provided for convenience in breaking the control loop and measuring the closed-loop response.
4
Test Setup and Results
This section describes how to properly connect, set up, and use the TPS54339EVM-056. The section also
includes test results typical for the evaluation modules and efficiency, output load regulation, output line
regulation, load transient response, output voltage ripple, input voltage ripple, start-up, and switching
frequency.
4.1
Input/Output Connections
The TPS54339EVM-056 is provided with input and output connectors and test points as shown in
.
A power supply capable of supplying 2 A must be connected to J1 through a pair of 20 AWG wires. The
load must be connected to J2 through a pair of 20 AWG wires. The maximum load current capability is 3
A. Wire lengths must be minimized to reduce losses in the wires. Test point TP1 provides a place to
monitor the V
IN
input voltages with TP2 providing a convenient ground reference. TP8 is used to monitor
the output voltage with TP9 as the ground reference.
Table 4. Connection and Test Points
Reference Designator
Function
J1
V
IN
(see
for V
IN
range)
J2
V
OUT
, 1.05 V at 3-A maximum
JP1
EN control. Connect EN to OFF to disable, connect EN to ON to enable
TP1
V
IN
test point at V
IN
connector
TP2
GND test point at V
IN
connector
TP3
EN test point
TP4
Loop response measurement test point
TP5
VREG5 test point
TP6
Switch node test point
4
TPS54339EVM-056, 3-A, Regulator Evaluation Module
SLVU836 – January 2013
Copyright © 2013, Texas Instruments Incorporated