Buttons
2
Buttons
There are eight buttons for controlling the output waveform settings. They are listed in
Table 1. Buttons
Button
Functionality
PHASE_BUTTON
Each time the button is pressed, the current INPx pattern becomes the pattern for INNx, the current
INNx pattern becomes the pattern for INPx.
PRF_BUTTON
Changes the Pulse Repetition Frequency of the output waveform as given in
Each press
increases the PRF and then cycles back to 0.
CYCLE_BUTTON
Changes the number of times the output pattern cycles within the pulse burst, as given in the
.
Each press moves 1 level up and then back to 0
FREQ_BUTTON
Changes the Frequency of the output waveform as given in the
Each press increases the
frequency and then cycles back to 0
RESET_BUTTON
Reset all the setting to its default
PDM_BUTTON
One press changes the mode to Power down mode.
CW_MODE_BUTTON
First six times the button is pressed will change the pattern depth as shown in
Seventh press
will change the device to CW mode. In CW mode, pressing the button will revert back to 17-level. The
latch mode is unaffected. Refer to
and
.
LATCH_MODE_BUTTON
First press changes to latch mode. Every consecutive pulse will toggle the mode between Latch and
Non latch mode
Table 2. PRF
Index
PRF(kHz)
Comments
0
0.5
1
1
2
5
17-level Ramp Only
3
10
17-level Ramp Only
Table 3. Cycle
Index
PRF (kHz)
Comments
0
1
Longer than 5-level Only
1
2
Longer than 5-level Only
2
3
3
5
4
10
Table 4. Frequency
Index
Frequency (MHz)
Comments
0
10
1
20
2
50
3
100
10
TX517 Dual Channel, 17-Level With RTZ, Integrated Ultrasound Transmitter