Texas Instruments Evaluation Module for TPS40322 TPS40322EVM-074 TPS40322EVM-074 Datenbogen

Produktcode
TPS40322EVM-074
Seite von 25
Test Setup
5
Test Setup
5.1
Test Equipment
Voltage Source: The input DC voltage source (V
SOURCE
) shall be a 0-V to 15-V variable DC source
capable of 10 A
DC
at 4.5 V
DC
. Connect V
SOURCE
to J1 as shown in
.
Multimeters:
Volt meter, V1: 0 V
DC
to 15 V
DC
for input voltage measurement.
Volt meter, V2: 0 V
DC
to 5 V
DC
for output voltage measurement.
Current meter, A1: 0 V
DC
to 10 A
DC
for input current measurement.
Current meter, A2: 0 A
DC
to 30 A
DC
for output current measurement.
Current shunt: a resistive shunt (i.e. 1-V/100-A shunt) may be used instead of A2 to monitor the
output current. When using a resistor shunt, a volt meter, V3, shall be used to measure the voltage
drop across the shunt in order to monitor the output current.
Output Load: Load, an electronic constant current mode load capable of 0 A
DC
to 30 A
DC
at 1.2 V shall be
used for LOAD
Oscilloscope: A digital or analog oscilloscope can be used to measure the ripple voltage on VOUT. The
oscilloscope should be set for 1-M
Ω
impedance, 20-MHz bandwidth, AC coupled. Test points TP8 and
TP20 or test points TP7 and TP22 can be used to measure the ripple on V
OUT
. Use the tip and barrel
method sown in
to avoid inducing additional noise due to the large ground loop area that would
result from using the probes ground lead.
Recommended Wire Gauge:
V
SOURCE
to J1: The connection from V
SOURCE
to the J1 connector of the EVM can carry as much as 10
A
DC
. The wire gauge shall be 14 AWG minimum and no longer than 2 feet for each connection,
V
SOURCE
+ to J1+, and V
SOURCE
- to J1-.
EVM to LOAD: The connection from J3 of the EVM to the LOAD can carry as much as 30 A
DC
. The
wire gauge shall be two 10 AWG wires in parallel and no longer than 2 feet for each connection, J3 to
Load+, including the current meter or the shunt, and LOAD- to J5.
Fan: This evaluation module includes components that can get hot to the touch. A small fan capable of
200 LFM to 400 LFM is required at all times during testing.
5.2
Recommended Test Setup
Shown in
is the basic test set up recommended to evaluate the TPS40322EVM-074.
Working at an ESD workstation, make sure that any wrist straps, bootstraps or mats are connected
referencing the user to earth ground before power is applied to the EVM. Electrostatic smock and safety
glasses should also be worn.
Input connections: Prior to connecting the DC input source, V
SOURCE
, it is advisable to limit the source
current from V
SOURCE
to 10 A maximum. Make sure V
SOURCE
is initially set to 0 V and connected as
shown in
.
Output connections: Connect Load to J3 and J5, as shown in
. Set LOAD to constant current
mode to sink 0 A before V
SOURCE
is applied. Connect voltmeter V2 across TP3 and TP4 as shown in
If using a shunt to monitor output current, connect the shunt in series with LOAD and connect
voltmeter V3 across it to monitor the output current.
Other connections: Place Fan as shown in
and turn on, making sure air is flowing across the
EVM at all times.