Texas Instruments Evaluation Module for TPS62690 TPS62690EVM-076 TPS62690EVM-076 Datenbogen

Produktcode
TPS62690EVM-076
Seite von 15
The trace on JP3 is closed
and LP1 is left open.
The trace on JP3 is cut and
a wire is installed on LP1.
Connector and Test Point Descriptions
3.1.7
J7
J7 S+/S
are the sense connections for the output of the converter. Connect a voltmeter, sense
connection of an electronic load, or oscilloscope to this header.
3.1.8
J8
J8 is the return connection of the converter. A load can be connected between J8 and J6 (VOUT).
3.2
Jumpers and Switches
3.2.1
JP1
ENABLE
This jumper enables/disables the converter on the EVM. Placing a shorting jumper between ENABLE and
ON turns on the converter. Placing a shorting jumper between ENABLE and OFF disables the converter.
3.2.2
JP2
MODE
This jumper enables/disables the power-saving mode under light loads. Placing a shorting jumper
between MODE and PWM disables the power-saving mode. If the power-save mode is disabled, the
converter operates in forced PWM mode over the entire load current range.
Placing a shorting jumper between MODE and PSM enables the power-saving mode. This causes the
device to operate in power-saving mode under light loads and in PWM mode in heavy loads. See the
specific device data sheet for detailed information.
3.2.3
JP3 and LP1
This is the inductor current loop. In order to measure the inductor current, the trace on JP3 needs to be
cut and a wire needs to be placed between the two ends of LP1. If the loop is no longer needed, remove
the wire on LP1 and shorting JP3.
Figure 2. JP3 and LP1 Set Up
4
TPS6269xEVM-076 Evaluation Module
SLVU529A
September 2011
Revised November 2011
Copyright
©
2011, Texas Instruments Incorporated