Texas Instruments Evaluation Module for TPS62691 TPS62691EVM-076 TPS62691EVM-076 Datenbogen

Produktcode
TPS62691EVM-076
Seite von 15
+
-
Oscilloscope
Load
EN
ON
OFF
JP1
VIN
GND
TPS6269xEVM
S+
S-
S+
S-
GND
VOUT
JP2
MODE
PSM
PWM
J1
J2
J3
J6
J7
J8
DC
Power Supply
Test Configurations
4
Test Configurations
4.1
Hardware Setup
illustrates a typical hardware test configuration.
Figure 3. Hardware Board Connection
4.2
Procedure
Follow these procedures when configuring the EVM for testing.
CAUTION
Many of the components on the TPS62690EVM-076 and TPS62691EVM-076
are susceptible to damage by electrostatic discharge (ESD). Customers are
advised to observe proper ESD handling precautions when unpacking and
handling the EVM, Including the use of a grounded wrist strap, bootstraps, or
mats at an approved ESD workstation. An electrostatic smock and safety
glasses should also be worn.
1. Work at an ESD workstation. Make sure that any wrist straps, bootstraps, or mats are connected and
secure the user to earth ground before power is applied to the EVM. Electrostatic smock and safety
glasses should also be worn.
2. Connect a dc power supply between J1 and J3 on the TPS62690/1/2/3EVM. Note that the input
voltage must range from 2.3 V to 4.8 V. Keep the wires from the input power supply to the EVM
twisted and as short as possible.
3. Connect a dc voltmeter or oscilloscope to the output sense connection of the EVM.
4. A load can be connected between J6 and J8 on the TPS62690/1/2/3EVM.
5. To enable the converter, connect the shorting jumper on JP1 between ENABLE and ON located on the
TPS62690/1/2/3EVM.
6. Use jumper JP2 to switch the TPS62690/1/2/3EVM between power-save mode under light loads and
forced PWM mode.