Texas Instruments TPS62351EVM-122 Evaluation Module TPS62351EVM-122 TPS62351EVM-122 Datenbogen

Produktcode
TPS62351EVM-122
Seite von 21
www.ti.com
Host
Computer
USB Cable
Green LED
Indicates
Power
EVM Board
10 Pin Ribbon
Cable
USB
Interface
Adapter
3
Operation
3.1
Operation
Operation
Figure 1. Quick Connection Diagram USB Interface Adapter
Connect an input voltage supply to the TPS62351EVM board. The TPS62351 uses an input voltage
between 2.7 V and 5.5 V. Connect the positive input voltage to J1 for converter 1 or J4 for converter 2.
Connect the input voltage return (ground) connection to J2 for converter 1 or J5 for converter 2.
This section provides descriptions of the EVM Software.
The supplied software is used to communicate with the TPS62351 EVM. Click on the icon on the host
computer to start the software. If there is no icon on the host computer then use the start button in the
lower left hand corner of the screen to browse the program folders to find the software. Once started, the
software will ask which version of the IC is on the board. Check the TPS62351 box and click the continue
box. The software displays the main control panel for the user interface. When initialized, the host
computer software automatically searches the internet (if connected) for updates. If a new update is
available, the software will notify the user of the update, and downloads the update.
The main control panel for the user interface has three main page tabs, EVM ConfigurationOutput
Controls 
and Preferences. The software will initialize with the EVM Configuration tab selected. This page
can be used to set register values that correspond to the hardware configuration of the EVM. The EVM
can be operated with the default values.
shows the user interface with the Output Control tab selected. The TPS62351 powers up with the
output disabled no matter how ENABLE jumper is configured. The ENABLE jumper must be set to
ENABLED in order for the TPS62351EVM software to communicate with the IC. Once the ENABLE
jumper is set to ENABLE, the software can be used to turn on the output of the converter. Push the
EN_DCDC button on the Output Control tab to turn the output of the converter on.
The Output Control tab is used to change the output voltage of the TPS62351 via the register settings.
The page has two pull down boxes, one for VSEL0 and one for VSEL1, with the available output voltage.
The voltages listed in the boxes assume PWM mode of operation, so the actual output voltage of the EVM
varies from the listed values at light loads.
6
TPS62351EVM
SLVU186 – October 2006