EVM Hardware and Software Setup
Use
the Data Flash Screen to configure the settings.
Figure 10. Data Flash Screen, Gas Gauging Class
Click on menu option | Data Flash Read All | to read all the data from the bq34z110 data flash.
Write to a data flash location by clicking on the desired location and entering the data. Clicking Enter
writes the entire tab of flash data. Writing to a data flash location can also be accomplished by selecting
menu option | Data Flash Write All |. The data flash must be read before any writes are performed to
avoid having incorrect data written to the device.
The | File Special Export | menu option allows the data flash to be exported.
Save the data flash configuration to a file by selecting | File Export | and entering a file name. A data
flash file also can be retrieved in this way, imported, and written to the bq34z110 using the Write All
button.
The configuration information of the bq34z110 data is held in the data flash.
The bq34z110 allows for an automatic data flash export function, similar to the Data RAM logging
function. This feature, when selected using | Options Auto Export |, exports data flash to a sequential
series of files named FilenameNNNNN.gg; where N = a decimal number from 0 to 9.
The AutoExport interval is set under the | Options menu | with a minimum value of 15 s. The AutoExport
filename is set under the | Options menu |.
When a check is next to | AutoExport |, the AutoExport is in progress. The same menu selection is used
to turn AutoExport on and off.
If the data-flash screen is blank, the bq34z110 used may not be supported by the bqEVSW version in use.
An upgrade may be required.