Electrical Performance
3
Electrical Performance
Table 1. Electrical Performance
(1) (2) (3)
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
INPUT CHARACTERISTIC
V
I
Input Voltage
108
265
V
rms
F
Line frequency
48
65
Hz
I
I
Input current
8
A
rms
p.f.
Power factor
0.95
OUTPUT CHARACTERISTIC
PFC Stage:
V
o(HVDC)
Output voltage
390
V
dc
LLC resonant stage:
V
I(HVDC)
Input voltage
330
410
V
dc
V
o
Output voltage
50
I
o
Output current
1
12
A
I
o, peak
Peak output current
20
P
o
Output power
Continuously
250
W
Maximum for 5min
600
Peak 20mS
1000
I
LIM
Current limit
26
A
P
LIM
Power limit
700
W
di/dt
Output current slew rate
Do not exceed maximum slew rate
11
A
200
ms
SYSTEM CHARACTERISTIC
η
Full load efficiency
110 V
ac
, 80% load
88%
η
Nom load efficiency
230 V
ac
, 50% load
91%
t
HOLD
Hold-up time
Nominal V
I
, 20% load
20
ms
OV
THLD
Over-voltage threshold
OV shutdown and restart
55
V
Temperature range
National Conv airflow
0
50
°C
(1)
Operates down to zero load with reduced regulation.
(2)
Forced Air cooling can be needed depending on the housing in which the SMPS is used – the temperature warning open drain
output signal can be used to control a fan.
(3)
The 50-V output will not power up, unless the ±15-V outputs are loaded. It is recommended that you load these outputs with 75
Ω
during power up.
6
A 600-W, Isolated PFC Power Supply for AVR Amplifiers Based on the
SLOU293C – June 2010 – Revised September 2012
TAS5630 and TAS5631
Copyright © 2010–2012, Texas Instruments Incorporated