Texas Instruments LMP8480 and LMP8481 Evaluation Tool LMP8480MEVM-S/NOPB LMP8480MEVM-S/NOPB Datenbogen

Produktcode
LMP8480MEVM-S/NOPB
Seite von 17
 
 
 
 
LMP8480/81 User’s Guide  
 
 
 
 
 
 
            
 
              March 2013 
 
 
 
 
 
 
            
 
 
4.  Board Test Procedure for Uni-Directional Devices (LMP8480-S) 
 
Required Equipment: 
 
•  1 ea.  20V, >1A power supply 
•  2 ea.  4.5 digit or better DMM (Agilent 34401 or equiv) 
•  1 ea.  20 ohm, >25W power resistor or programmable load sinking 1A. 
•  Misc test leads for connections. 
 
Connect board as shown, but do not connect SENSE- to load yet. 
 
1.  Connect 20V power supply as VSOURCE (turn off power for now). 
2.  Connect DMM1 to the output and ground terminals (+ to output, - to GND) 
3.  Connect DMM2 to the TP1 terminals or sense terminals (+ to RSP, - to RSN) 
4.  Confirm SENSE- is not connected and turn on power. 
5.  DMM1 should be between 0V and 5.5mV. 
6.  Now connect RLOAD to SENSE- as shown. 
7.  Record reading from DMM1 (should be around 6V for the “S” device) 
8.  Record reading from DMM2 (should be around 100mV – depending on accuracy of RLOAD) 
9.  The reading of DMM1 should be within 0.1% of the gain (60 for “S” version) times the DMM2 reading. 
10.  Turn off Vsource or disconnect RLOAD to prevent excessive heating. 
 
Keep in mind that heating of the load and sense resistors may cause drift between steps 7 and 8. DMM 
measurements should be taken quickly or simultaneously (use manual trigger function to trigger the readings 
at the same time).  
 
-
+
RLOAD
VSOURCE
DMM 1
DMM 2
-+
+
-
 
Figure 8: Setup for Uni-Directional Devices