Texas Instruments TPS65001EVM-453 Evaluation Module TPS65001EVM-453 TPS65001EVM-453 Datenbogen

Produktcode
TPS65001EVM-453
Seite von 15
4
Connector and Test Point Description
4.1
JP1 –ENLDO1
4.2
JP2 – ENLDO2
4.3
JP3 –MODE
4.4
JP4 –ENDCDC
4.5
JP5 – MRPU
4.6
JP6 – VPU
4.7
JP7 – RSTSNSIN
4.8
J1 – PG/GND
www.ti.com
Connector and Test Point Description
Placing a shorting bar between ENLDO1 and ON ties the EN pin of LDO1 to VIN, thereby enabling LDO1.
Placing a shorting bar between ENLDO1 and OFF ties the EN pin of LDO1 to GND, thereby disabling
LDO1.
Placing a shorting bar between ENLDO2 and ON ties the EN pin of LDO2 to VIN, thereby enabling LDO2.
Placing a shorting bar between ENLDO2 and OFF ties the EN pin of LDO2 to GND, thereby disabling
LDO2.
JP3 selects the forced PWM or Power Save Mode (PSM) operation for the DCDC converter. Placing a
shorting bar between MODE and PWM ties the MODE pin of TPS65001 to VIN, thereby selecting forced
PWM operating mode for the DCDC converter. Placing a shorting bar between MODE and PFM ties the
MODE pin of TPS65001 to GND, thereby selecting Power Save Mode operating mode for the DCDC
converter at light-load conditions. If Power Save Mode is selected the DCDC converter will automatically
switch to PWM mode at heavier load conditions.
Placing a shorting bar between ENDCDC and ON ties the EN pin of the DCDC converter to VIN, thereby
enabling the DCDC converter. Placing a shorting bar between ENDCDC and OFF ties the EN pin of the
DCDC converter to GND, thereby disabling the DCDC converter.
JP5 selects the pull-up voltage for the Manual Reset input MR of the TPS65001. Placing a shorthing bar
between VIN and MRPU selects VIN as pull-up voltage. Any other voltage source can be used, by
removing the shorting bar and connecting a power supply between MRPU (positive connection) and GND
(negative connection). In the default setup VIN is used as pull-up voltage.
JP6 select the pull-up voltage used for the PG output.
Placing a shorting bar between VPU and VIN select VIN as pull-up voltage. Any other pull-up voltage can
be used by removing the shorting bar and connecting a power supply between VPU and GND.
JP7 selects the voltage rail that is monitored by the Supply Voltage Supervisor (SVS). Placing a shorting
bar between VIN and RSTSNSIN selects VIN as monitored rail. Any other voltage rail can be connected to
the SVS input by removing the shorting bar and connecting the rail between RSTSNSIN and GND.
In default setup VIN is monitored by the SVS.
J1 pin 1 is pulled to GND if the output voltages of the DCDC converter and both LDOs are > 90% of their
set point and all enable pins are pulled high.
J1 pin 1is pulled up to the selected pull-up voltage level if any of the output voltages VODC, VLDO1 or
VLDO2 is < 90% of its set point or all enable pins are pulled low.
SLVU320 – August 2009
Using the TPS65001EVM 2.25 MHz Step-Down Converter with Dual LDO
5