Texas Instruments PCM2707 Evaluation Module PCM2707EVM-U PCM2707EVM-U Datenbogen

Produktcode
PCM2707EVM-U
Seite von 40
SBFS036A – AUGUST 2011 – REVISED JULY 2012
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
ORDERING INFORMATION
For the most current specification and package information, refer to the Package Option Addendum located at
the end of this data sheet or see the respective device product folders at
ABSOLUTE MAXIMUM RATINGS
(1)
Over operating free-air temperature range unless otherwise noted.
VALUE
UNIT
V
BUS
–0.3 to 6.5
V
Supply voltage
V
CCP
, V
CCL
, V
CCR
, V
DD
–0.3 to 4
V
Supply voltage differences
V
CCP
, V
CCL
, V
CCR
, V
DD
±0.1
V
Ground voltage differences
PGND, AGNDL, AGNDR, DGND, ZGND
±0.1
V
HOST
–0.3 to 6.5
V
D+, D–, HID0/MS, HID1/MC, HID2/MD, XTI, XTO, DOUT,
Digital input voltage
SSPND, CK, DT, PSEL, FSEL, TEST, TEST0, TEST1,
–0.3 to (V
DD
+ 0.3) < 4
V
FUNC0, FUNC1, FUNC2, FUNC3
V
COM
–0.3 to (V
CCP
+ 0.3) < 4
V
Analog input voltage
V
OUT
R
–0.3 to (V
CCR
+ 0.3) < 4
V
V
OUT
L
–0.3 to (V
CCL
+ 0.3) < 4
V
Input current (any pins except supplies)
±10
mA
Ambient temperature under bias
–40 to +125
°C
Storage temperature
–55 to +150
°C
Junction temperature
+150
°C
Package temperature (IR reflow, peak)
+260
°C
(1)
Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating
Conditions 
is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Over operating free-air temperature range.
MIN
NOM
MAX
UNIT
V
BUS
4.35
5
5.25
Supply voltage
V
V
CCP
, V
CCL
, V
CCR
, V
DD
3
3.3
3.6
Digital input logic level
TTL-compatible
Digital input clock frequency
11.994
12
12.006
MHz
Analog output load resistance
16
32
Ω
Analog output load capacitance
100
pF
Digital output load capacitance
20
pF
Operating free-air temperature, T
A
–25
85
°C
2
Copyright © 2011–2012, Texas Instruments Incorporated