2.3
Quick Start List for Stand-Alone
www.ti.com
Operation
Table 2. Platform Jumper and Switch Settings for the TPA2036D1 EVM
EVM
JP6
JP7
JP8
S2
S3
TPA2036D1
Mute
X
(1)
Lo
See
(2)
X
(1)
X = Don't care
(2)
Set S2 to On when signal conditioning board is installed in U1; set S2 to Off when no signal conditioning board is installed.
Power Supply
6) Select and connect the power supply:
a. Connect an external regulated power supply set to a voltage between 2.5 V and 5.5 V to
platform V
DD
power input connector J6, taking care to observe marked polarity,
OR
b. Install a voltage regulator EVM (SLVP097 or equivalent.) in platform socket U6. Install a
9-V battery in B1 or connect a 7 V-12 V power source to a platform VCC power input J1
or J2 and jumper the appropriate power input (see platform user's guide).
Inputs and Outputs
7) Ensure that signal source level is set to minimum.
8) Connect the audio source to left (J5) or right (J3) RCA phono jacks, or both if using two
TPA2036D1 modules, or to stereo miniature phone jack (J4).
9) Connect 4-
Ω
to 32-
Ω
speakers to left (J9) or right (J7) RCA jacks, or both if using two
TPA2036D1 modules, or to stripped wire connector (J8).
Power Up
10) Verify correct voltage and input polarity and set the external power supply to ON. If V
CC
and
an on-board regulator EVM are used to provide V
DD
, set platform power switch S1 to On.;
Platform LED2 lights, indicating the presence of VDD, and the evaluation modules installed on
the platform begin operation.
11) Adjust the signal source level as needed.
Follow these steps to use the TPA2036D1 EVM stand-alone or when connecting it into existing circuits or
equipment. Connections to the TPA2036D1 module header pins can be made via individual sockets,
wire-wrapping, or soldering to the pins, either on the top or the bottom of the module circuit board.
Power Supply
1) Ensure that all external power sources are set to OFF.
2) Connect an external regulated power supply set to 5 V to the module VDD and GND pins,
taking care to observe marked polarity.
Inputs and Outputs
3) Ensure that the signal source level is set to minimum.
4) Connect the positive lead from the audio source to the module IN+ pin and the negative lead
to the IN– pin.
5) SHUTDOWN can be enabled by either pressing switch S1, or by driving the SHUTDOWN
EVM pin with TTL level logic.
6) Connect a 4-
Ω
to 32-
Ω
speaker to the module VO+ and VO– pins.
Power Up
7) Verify correct voltage and input polarity and set the external power supply to ON.
SLOU238 – August 2008
TPA2036D1 Audio Power Amplifier Evaluation Module
5