Texas Instruments LM4570 Evaluation Board LM4570LQBD/NOPB LM4570LQBD/NOPB Datenbogen

Produktcode
LM4570LQBD/NOPB
Seite von 14
SNOSAV2C – APRIL 2006 – REVISED APRIL 2013
Electrical Characteristics V
DD
= 5V
(1) (2)
The following specifications apply for V
DD
= 5V, A
V-BTL
= 6dB unless otherwise specified. Limits apply for T
A
= 25°C.
LM4570
Units
Parameter
Test Conditions
(Limits)
Typ
(3)
Limit
(4) (5)
V
IN
= 0V, I
L
= 0A, No Load
2.5
5.5
mA (max)
I
DD
Quiescent Power Supply Current
V
IN
= 0V, I
L
= 0A, R
L
= 30
Ω
2.6
5.5
mA (max)
I
SD
Shutdown Current
V
SD
= GND
0.1
1.5
µA (max)
V
IH
Logic Input High
1.4
V (min)
V
IL
Logic Input Low
0.4
V (max)
V
OS
Output Offset Voltage
5
±35
mV (max)
I
OUT
Output Current
V
OH
, V
OL
250mV
268
mA
T
WU
Wake-up time
2.5
ms (max)
R
L
= 30
Ω
specified as
V
OH
Output High Voltage
146
200
mV (max)
|V
DD
- V
OH
|
R
L
= 30
Ω
specified as
V
OL
Output Low Voltage
106
200
mV (max)
|GND + V
OH
|
(1)
All voltages are measured with respect to the ground pin, unless otherwise specified.
(2)
Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for
which the device is functional, but do not specify specific performance limits. Electrical Characteristics state DC and AC electrical
specifications under particular test conditions which specify specific performance limits. This assumes that the device is within the
Operating Ratings. Specifications are not specified for parameters where no limit is given; however, the typical value is a good indication
of device performance.
(3)
Typicals are measured at 25°C and represent the parametric norm.
(4)
Limits are ensured to AOQL (Average Outgoing Quality Level).
(5)
Datasheet min/max specification limits are ensured by design, test, or statistical analysis.
Electrical Characteristics V
DD
= 3V
(1) (2)
The following specifications apply for V
DD
= 3V, A
V-BTL
= 6dB unless otherwise specified. Limits apply for T
A
= 25°C.
LM4570
Units
Parameter
Test Conditions
(Limits)
Typ
(3)
Limit
(4) (5)
V
IN
= 0V, I
L
= 0A, No Load
1.9
4
I
DD
Quiescent Power Supply Current
mA (max)
V
IN
= 0V, I
L
= 0A, R
L
= 30
Ω
1.95
4
I
SD
Shutdown Current
(6)
V
SD
= GND
0.1
1.0
µA (max)
V
IH
Logic Input High
1.4
V (min)
V
IL
Logic Input Low
0.4
V (max)
V
OS
Output Offset Voltage
5
±35
mV (max)
I
OUT
Output Current
V
OH
, V
OL
200mV
192
mA
T
WU
Wake-up time
2.4
ms (max)
R
L
= 30
Ω
specified as
V
OH
Output High Voltage
90
110
mV (max)
|V
DD
- V
OH
|
R
L
= 30
Ω
specified as
V
OL
Output Low Voltage
63
110
mV (max)
|V
DD
- V
OH
|
(1)
All voltages are measured with respect to the ground pin, unless otherwise specified.
(2)
Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for
which the device is functional, but do not specify specific performance limits. Electrical Characteristics state DC and AC electrical
specifications under particular test conditions which specify specific performance limits. This assumes that the device is within the
Operating Ratings. Specifications are not specified for parameters where no limit is given; however, the typical value is a good indication
of device performance.
(3)
Typicals are measured at 25°C and represent the parametric norm.
(4)
Limits are ensured to AOQL (Average Outgoing Quality Level).
(5)
Datasheet min/max specification limits are ensured by design, test, or statistical analysis.
(6)
Shutdown current is measured in a normal room environment. Exposure to direct sunlight will increase I
SD
by a maximum of 2
μ
A.
Copyright © 2006–2013, Texas Instruments Incorporated
3