Basic Test Procedure
Figure 4. Screen Shot of CDCM7005 Tab
2.2.3
General GUI Controls
The following is a summary of the various other GUI controls:
Reset USB Port. This button assigns a new handle for the USB connection. Use it whenever a device
communication failure occurs.
One Shot. This button can be enabled to run the program only once rather than as a loop.
Exit. This buttons exits the GUI.
Display Pane. This pane takes up most of the right side of the GUI and is used to display which
register settings are being written to or read from the AFE7070.
Register Controls
Send All. This command sends all the GUI settings to the AFE7070 and CDCM7005 registers.
Read All. This command reads back the register values of the AFE7070 and display them in the
display pane.
Load Regs. This command loads the contents of a text file into both the AFE7070 and CDCM7005
registers (as applicable).
Save All Regs. This command saves the AFE7070 and CDCM7005 register settings to a text file.
Save AFE Regs. This command saves the AFE7070 register settings to a text file.
Save CDC Regs. This command saves the CDCM7005 register settings to a text file.
3
Basic Test Procedure
This section outlines the basic procedure for testing the EVM.
3.1
Test Block Diagram
displays the test setup for general testing of the AFE7070 with the TSW3100 pattern generation
card.