Texas Instruments C2000 2 Phase Interleaved Power Factor Correction Kit with integrated power metering TMDSILPFCKIT TMDSILPFCKIT Datenbogen

Produktcode
TMDSILPFCKIT
Seite von 9
www.ti.com
The Role of the Inverter
Figure 3. Transformerless DC/AC Conversion Circuit
At some point, the DC input has to be at a higher voltage level than the AC output. If the PV input is not
high enough, the system can either step it up with a transformer on the AC side (after the coils in
)
or boost it in the DC/DC conversion stage. The AC transformer inherently provides galvanic isolation, as
does a phase-shifted full-bridge DC/DC converter with zero voltage switching (making it thus equivalently
a transformer).
shows the DC/AC circuit equivalent when either type of transformer is introduced.
This circuit is equivalent either to the bridge in
if the transformer is on the AC side, or to the
DC/DC converter in
if the transformer is on the DC side.
Figure 4. Equivalent Circuit with Transformer
4
TMS320C2000™ DSP Controllers: A Perfect Fit for Solar Power Inverters
SPRAAE3 – May 2006