Test Procedure
6.4
Control Architecture and OVP Select
1. All jumper modifications should be done with no power applied to the EVM.
2. The FUNC jumper (JP2) allows the user to select the control architecture the EVM uses to control the
output. It also enables or disables the OVP function.
describes each possible selection.
Table 4. FUNC (jumper JP2) Selections
JUMPER LOCATION
MODE
CMODE_ON (1 and 2 shorted) default
Current mode control and OVP enabled
DCAP_OFF (3 and 4 shorted)
D-Cap mode control and OVP disabled
DCAP_ON (5 and 6 shorted)
D-Cap mode control and OVP enabled
CMODE_OFF (7 and 8 shorted)
Current mode control and OVP disabled
3. Once a mode has been selected efficiency and regulation measurements may be retaken. Repeat
steps 3 to 11 of section
. The engineer should reduce the step current when the output is
less than 1 A.
shows typical data for the various modes of operation
6.5
Over Current Trip Level and Output Discharge Select
1. All jumper modifications should be done with no power applied to the EVM.
2. The TRIP jumper (JP3) allows the user to select the voltage level used by the EVM to implement
current limit. It also enables or disables the output discharge function.
describes each possible
selection.
Table 5. TRIP (JP3) Selections
JUMPER LOCATION
MODE
Over current uses ultra low voltage threshold (31 mV typical) and output
UL_D-ON (1 and 2 shorted)
discharge is enabled
Over current uses ultra low voltage threshold (31 mV typical) and output
UL_OFF (3 and 4 shorted)
discharge is disabled
Over current uses low voltage threshold (60 mV typical) and output discharge
LV_OFF (5 and 6 shorted)
is disabled
Over current uses low voltage threshold (60 mV typical) and output discharge
LV_D-ON (7 and 8 shorted) default
is enabled
3. Once a mode has been selected efficiency and regulation measurements may be retaken. Repeat
steps 3 to 11 of section
. The engineer should reduce the step current when the output is
less than 1 A.
shows typical data for the various modes of operation