Texas Instruments ISO1176TEVM - ISO1176T Evaluation Module ISO1176TEVM ISO1176TEVM Datenbogen

Produktcode
ISO1176TEVM
Seite von 18
Overview
www.ti.com
…."need not operate over the entire data signaling rate range specified nor be limited to 10Mbps. They
may be specified to operate at data rates to satisfy specific applications. The upper bound is application
dependent and beyond the scope of this standard. Maximum signaling rate is typically limited by the
following: ratio of signal transition time to the unit interval, maximum allowable stub length, and the
bandwidth of the interconnecting media."
PROFIBUS (Process Field Bus), developed subsequently, had several impacts on the electrical (physical)
layer including an increase in the receiver noise margin, to allow the bus to be used in an extremely noisy
(i.e., EMI-rich) environment. This was accomplished by increasing the minimum differential voltage on the
bus. The ISO1176T has been designed specifically for these types of environments. The two standards
are indeed very similar.
1.2
EVM Kit Contents
1.2.1
ISO1176TEVM Kit Contents
ISO1176TEVM circuit board with ISO1176TDW installed - (6510416-1)
This PCB is configured with a DA2304-AL transformer and LP2985A-50DBVR LDO for 3-V to 5-V
operation on the logic side of the device and 5-V operation on the bus side.
1.2.2
ISO35TEVM Kit Contents
ISO35TEVM circuit board with ISO35TDW installed – (6510416-2)
This PCB is configured with a DA2303-AL transformer and LP2985A-33DBVR for 3-V operation on the
logic and bus sides of the device.
1.2.3
ISO3086TEVM Kit Contents
ISO3086TEVM circuit board with ISO3086TDW installed - (6510416-3)
This PCB is configured with a DA2304-AL transformer and LP2985A-50DBVR LDO for 3-V to 5-V
operation on the logic side of the device and 5-V operation on the bus side.
The ISO1176T/35T/3086TEVM is shown in
4
ISO1176T/35T/3086T Evaluation Module
SLLU122A – April 2010 – Revised July 2010
Copyright © 2010, Texas Instruments Incorporated