Texas Instruments BQ51013AEVM-765 Integrated Wireless Power Receiver Solution, Qi Evaluation Module (QFN Package) BQ5101 BQ51013AEVM-765 Datenbogen

Produktcode
BQ51013AEVM-765
Seite von 21
+
-
V
Wireless
Transmitter
V
A
A
R
L
L
P
L
S
AC1
OUT-J3
V
I
VRECT-TP12
AC2
GND-J4
OUT-TP7
Wireless Receiver
bq51013AEVM-765
+ -
GND-J2
V-adapter-J1
Test Setup
6.1.3
Meters
Output voltage can be monitored at TP7 with a voltmeter. Input current into the load must be monitored
with an appropriate ammeter. Transmitter input current and voltage can be monitored also but the meter
must use averaging function for reducing error due to communications packets.
6.1.4
Loads
A single load is required for 5 V with a maximum current of 1 A. The load can be resistive or electronic.
6.1.5
Oscilloscope
A multichannel oscilloscope with appropriate probes is used to observe the RECT voltage at TP12 and
other signals.
6.1.6
Recommended Wire Gauge
For proper operation, 22 AWG wire is recommended when connecting the bq51013AEVM-765EVM to
loads.
6.2
Equipment Setup
With the power supply off, connect supply to the bqTESLA™ transmitter.
Place the bqTESLA™ receiver on the transmitter.
Connect load to J3 with return to J4, monitor current through load with ammeter, and monitor current to
load at TP7.
Typical output voltage is 5 V, and the output current range is 0 mA to 1 A.
6.2.1
Equipment Setup Diagram
The diagram of
shows the equipment test setup.
Figure 2. Equipment Setup
7
SLUU911A – June 2012 – Revised October 2012
bq51013AEVM-765 Evaluation Module (QFN Package)
Copyright © 2012, Texas Instruments Incorporated