Texas Instruments 2A, SWIFT (tm) Converter Evaluation Module TPS54233EVM-373 TPS54233EVM-373 Datenbogen

Produktcode
TPS54233EVM-373
Seite von 15
1.3
Modifications
1.3.1
Output Voltage Set Point
6
0.8
10.2
0.8
=
W ´
-
Out
V
R
k
V
V
(1)
2
Test Setup and Results
2.1
Input / Output Connections
www.ti.com
Test Setup and Results
These evaluation modules are designed to provide access to the features of the TPS54233. Some
modifications can be made to this module.
To change the output voltage of the EVM, it is necessary to change the value of resistor R
6
. Changing the
value of R
6
can change the output voltage above 0.8 V. The value of R
6
for a specific output voltage can
be calculated using
lists the R
6
values for some common output voltages. Note that V
IN
must be in a range so that the
minimum on-time is greater than 160 ns, and the maximum duty cycle is less than 90%. The values given
in
are standard values, not the exact value calculated using
.
Table 3. Output Voltages Available
Output Voltage
R
6
Value (k
Ω
)
(V)
1.8
8.25
2.5
4.75
3.3
3.24
5
1.96
This section describes how to properly connect, set up, and use the TPS54233EVM-373 evaluation
module. The section also includes test results typical for the evaluation module and covers efficiency,
output voltage regulation, load transients, loop response, output ripple, input ripple, and start-up.
The TPS54233EVM-373 is provided with input/output connectors and test points as shown in
. A
power supply capable of supplying 2 A must be connected to J1 through a pair of 20 AWG wires. The load
must be connected to J4 through a pair of 20 AWG wires. The maximum load current capability must be 2
A. Wire lengths must be minimized to reduce losses in the wires. Test-point TP1 provides a place to
monitor the V
IN
input voltages with TP2 providing a convenient ground reference. TP5 is used to monitor
the output voltage with TP6 as the ground reference.
SLVU264 – November 2008
TPS54233EVM-373 2-A, SWIFT™ Regulator Evaluation Module
3