Texas Instruments TPS2543 USB Charging Port Power Switch & Controller Evaluation Module TPS2543EVM-064 TPS2543EVM-064 Datenbogen

Produktcode
TPS2543EVM-064
Seite von 16
TPS2543EVM
J2
J3
D1
D3
PC (USB charging source)
PD
J1
D2
J3
General Configuration and Description
Table 4. TPS2543 Mode Truth Table
CTL1
CTL2
CTL3
ILIM_SEL
Mode
0
0
0
X
OUT discharge, power switch OFF
0
0
1
0
Dedicated charging port, auto-detect, without power-wake function
0
0
1
1
Dedicated charging port, auto-detect, with power wake function
(1)
0
1
1
0
Dedicated charging port, auto-detect, with load detection disabled
0
1
1
1
Dedicated charging port, auto-detect, with load detection enabled
(2)
1
0
0
X
Dedicated charging port, BC 1.2 only, ILIM_HI or ILIM_LO is selected to set I
OS
by ILIM_SEL.
1
0
1
X
Dedicated charging port, Divider1 mode only, ILIM_HI or ILIM_LO is selected to
set I
OS
by ILIM_SEL.
X
1
0
X
Standard downstream port, USB 2.0 mode, ILIM_HI or ILIM_LO is selected to
set I
OS
by ILIM_SEL.
1
1
0
1
Standard downstream port, USB 2.0 mode, ILIM_LO is selected to set I
OS
, no
discharge to or from 1111
1
1
1
1
Charging downstream port, BC 1.2, with load detection enabled
(2)
(1)
Current limit (I
OS
) is automatically changed, I
OS
is I
OS_PW
while no load, I
OS
is switched to the value set by ILIM_HI and STATUS is
active-low while with load
(2)
ILIM_HI is selected to set I
OS
, ILIM_LO is selected to set load-detection current threshold (I
LD
)
3.2
Test Setup
shows a typical test setup for TPS2543EVM. Connect J2 to the PC either directly (insert J2 into
available/accessible PC USB port) or using any Type A Male to Type A Female USB v2.0 extension cable.
USB power and data are available at J3.
Figure 2. Typical TPS2543EVM Test Setup