Texas Instruments BQ2419X I²C Controlled 4.5A Single Cell USB / Adaptor Charger Evaluation Module BQ24195EVM-193 BQ24195EVM-193 Datenbogen

Produktcode
BQ24195EVM-193
Seite von 41
VREF
COLD
HOT
LTF
TCO
VREF
VREF
HOT
COLD
TCO
LTF
VREF
LTF
COLD
1
1
V
RTH
RTH
V
V
 RT2
V
V
RTH
1
RTH
1
V
V
V
1
V
RT1
1
1
RT2
RTH
æ
ö
´
´
´
-
ç
÷
è
ø
=
æ
ö
æ
ö
´
-
-
´
-
ç
÷
ç
÷
è
ø
è
ø
-
=
+
TEMPERATURE RANGE TO
INITIATE CHARGE
TEMPERATURE RANGE
DURING A CHARGE CYCLE
CHARGE SUSPENDED
CHARGE SUSPENDED
VREF
VREF
V
LTF
CHARGE at full C
CHARGE at full C
V
HTF
V
TCO
CHARGE SUSPENDED
CHARGE SUSPENDED
AGND
AGND
V
LTFH
V
LTFH
V
LTF
SLUSB97 – OCTOBER 2012
Figure 21. TS Pin Thermistor Sense Thresholds
Assuming a 103AT NTC thermistor is used on the battery pack , the value RT1 and RT2 can be determined by
using the following equation:
(1)
Select 0°C to 45°C range for Li-ion or Li-polymer battery,
RTH
COLD
= 27.28 k
Ω
RTH
HOT
= 4.911 k
Ω
RT1 = 5.52 k
Ω
RT2 = 31.23 k
Ω
Charging Termination
The bq24195L, bq24195 terminates a charge cycle when the battery voltage is above recharge threshold, and
the current is below termination current. After the charging cycle is complete, the BATFET turns off. The
converter keeps running to power the system, and BATFET can turn back on to engage supplement mode.
When termination occurs, the status register REG09[5:4] is 11, and an INT is asserted to the host. Termination is
temporarily disabled if the charger device is in input current/voltage regulation or thermal regulation. Termination
can be disabled by writing 0 to REG05[7].
Termination when REG02[0] = 1
When REG02[0] is HIGH to reduce the charging current by 80%, the charging current could be less than the
termination current. The charger device termination function should be disabled. When the battery is charged to
fully capacity, the host disables charging through CE pin or REG01[5:4].
Copyright © 2012, Texas Instruments Incorporated
25
Product Folder Links: