Texas Instruments Evaluation Module for TPS82695 TPS82695EVM-646 TPS82695EVM-646 Datenbogen

Produktcode
TPS82695EVM-646
Seite von 13
Connector and Test Point Descriptions
3.1.4
J4 VOUT
This header is the positive output of the step-down converter. The output voltage of the devices in the
TPS826xx families have fixed output voltages; refer to the specific device data sheet for detailed
information on the device output voltage.
3.1.5
J5 S+/S
J5 S+/S
are the sense connection for the output of the converter. Connect a voltmeter, sense connection
of an electronic load, or oscilloscope to this header.
3.1.6
J6 GND
J6 is the return connection of the converter. A load can be connected between J6 and J4 (VOUT).
3.2
Jumpers and Switches
3.2.1
JP1 ENABLE
This jumper enables/disables the converter on the EVM. Placing a shorting bar between ENABLE and ON
turns on the converter. Placing a shorting bar between ENABLE and OFF disables the converter.
3.2.2
JP2 MODE
This jumper enables/disables the power-saving mode under light loads. Placing a shorting bar between
MODE and PWM disables the power-saving mode. If the power-save mode is disabled, the converter
operates in forced PWM mode over the entire load current range.
Placing a shorting bar between MODE and PSM enables the power-saving mode. The device operates in
power-saving mode under light load conditions. See the specific device data sheet for detailed information.
4
TPS826xxEVM
SLVU383D
October 2010
Revised November 2011
Copyright
©
2010
2011, Texas Instruments Incorporated