Texas Instruments TSC2017 Performance Demonstration Kit TSC2017EVM-PDK TSC2017EVM-PDK Datenbogen

Produktcode
TSC2017EVM-PDK
Seite von 20
www.ti.com
EVM Operation
If laboratory supplies are used to provide the individual voltages required by the USB-MODEVM interface
board, JMP6 must have no shunt installed. Voltages then are applied to J2 (+5 VA), J3 (+5 VD), J4 (+1.8
VD), and J5 (+3.3 VD). The +1.8 VD and +3.3 VD also can be generated by the onboard regulators from
the +5-VD supply; to enable this supply, the switches on SW1 must be set to enable the regulators by
placing them in the ON position (lower position, looking at the board with text reading right side up). If +1.8
VD and +3.3 VD are supplied externally, disable the onboard regulators by placing SW1 switches in the
OFF position.
Each power supply voltage has an LED (D1-D7) that lights when the power supplies are active.
5
EVM Operation
This section provides information on the analog input, digital control, and general operating conditions of
the TSC2017EVM.
5.1
Analog Input
The analog input sources (touch screen and auxiliary input) can be applied directly to J1 (top or bottom
side) or through signal-conditioning modules available for the modular EVM system.
5.2
Digital Control
The digital control signals can be applied directly to J2 (top or bottom side). The modular TSC2017EVM
also can be connected directly to a DSP or microcontroller interface board, such as the USB-MODEVM
interface board if purchased as part of the TSC2017EVM-PDK. See the
for the
TSC2017 for a current list of compatible interface and/or accessory boards.
5.3
Default Jumper Locations
provides a list of jumpers found on the EVM and the resepctive factory default conditions.
Table 5. List of Jumpers
Jumper
Shunt Position
Jumper Description
JP1
1-2
Analog power select (default is +3.3 VD)
JP2
Closed
EEPROM address select. When installed and used with the USB-MODEVM, firmware for the
motherboard is executed from the EEPROM on the TSC2017EVM. This is the default mode.
JP3
Closed
TSC2017 I
2
S slave address A0 bit (default is 1001000b)
6
EVM-PDK Operation
This section provides information on operating the TSC2017EVM-PDK, including setup, program
installation, and the GUI and its operation description.
6.1
TSC2017EVM-PDK Setup
6.1.1
Hardware Setup
A TSC2017EVM-PDK includes three components: (1) the TSC2017EVM circuit board; (2) the
USB-MODEVM circuit board; and (3) a CDROM with TSC2017EVM-PDK installer and related
documentation.
5
SLAU305A – January 2010 – Revised June 2010
TSC2017EVM and TSC2017EVM-PDK
Copyright © 2010, Texas Instruments Incorporated