Texas Instruments ISO71XXDBQ - 4242 VPK Small-Footprint and Low-Power Digital Isolator Evaluation Module ISO71XXDBQ-EVM ISO71XXDBQ-EVM Datenbogen

Produktcode
ISO71XXDBQ-EVM
Seite von 13
Table 1. Bill of Materials
Designator
Value
Description
Package
MFG
C1-C8
Not populated
Capacitor
0805
Any
User selectable
(1)
C10, C13
1
μ
F
Power Supply
0603
Any
Decoupling Capacitors
C11, C14
0.1uF
Power Supply
0402
Any
Decoupling Capacitors
C9, C12
10uF
Power Supply
1206
Any
Decoupling Capacitors
U1
ISO7131CC
Digital Isolator
16-DBQ
TI
JMP1, JMP4, JMP5,
1 x 4 Jumper
Jumper
0.1”
Any
JMP8, JMP9, JMP12,
JMP15, JMP18
JMP2, JMP3, JMP6,
1 x 3 Jumper
Jumper
0.1”
Any
JMP7, JMP10, JMP11,
JMP13, JMP14, JMP16,
JMP17
R1-R8
Not populated
Resistor
0805
Any
User selectable
(1)
TB1, TB2
2-pin female
Terminal block
0.1”
Any
(1)
Refer to the device datasheet (
for allowable load values.
EVM Setup and Operation
The basic setup has two power supplies (TB1, TB2, P1-P4) to evaluate isolator performance with any
combination of 2.7 V, 3.3 V, or 5 V for VCC1 and VCC2. If both sides are to be evaluated at the same
supply voltage, only one power supply is required and can be used to power both sides of the EVM.
CAUTION
Note that although these devices provide galvanic isolation of up to 3000 Vrms,
this EVM cannot be used for isolation voltage testing. It is designed for the
evaluation of device operating parameters only and may be damaged if a
voltage exceeding 5.5 V is applied anywhere in the circuit.
For the ISO7131, ISO7141, and ISO7142 isolators, JMP13 and JMP14 should be set to VCC1 and VCC2,
respectively, for normal operation.
For the ISO7140, JMP14 should be set to VCC2 for normal operation (JMP13 is not needed).
8
ISO71xx EVM User’s Guide
SLLU179 – March 2013
Copyright © 2013, Texas Instruments Incorporated