Texas Instruments HV Resonant LLC Developer’s Kit TMDSHVRESLLCKIT TMDSHVRESLLCKIT Datenbogen

Produktcode
TMDSHVRESLLCKIT
Seite von 11
Hardware Overview
Demo Mode: Uses the GUI to quickly show how the board functions. All power used by the board is
provided from a single 390V DC power supply.
1. Insert a pre-flashed F28027 control card into socket [Main]-H1.
2. Connect your computer to the board using a USB cable.
3. Verify the following jumper settings:
(a) Jumpers are placed on [Main]-J1, J2, J3, J4, J5.
(b) Jumpers are placed on pins 1-2 on [Main]-J7, J8.
(c) A jumper is placed on [M4]-J4.
(d) No jumper is placed on [Main]-J6.
4. Verify that no DC power supply is connected to [M3]-JP1.
5. Connect a 390 V DC power supply across [Main]-BS1, BS2.
6. Connect a load across [Main]-BS3, BS4.
Experimentation Mode: Uses CCSv4 to experiment with how the board functions. Two different
power supplies are used to minimize the risk of damage while experimenting. The primary and
auxiliary power rails will each use a separate power supply. This mode allows the user to verify PWM
output and ADC feedback signals before energizing the DC/DC power stage and helps protect the
MCU if a fault occurs on the primary power rail.
1. Insert a F28027 control card into socket [Main]-H1.
2. Connect your computer to the board using a USB cable.
3. Verify the following jumper settings:
(a) Jumpers are placed on [Main]-J3, J4, J5, J6.
(b) Jumpers are placed on pins 1-2 on [Main]-J7, J8.
(c) A jumper is placed on [M4]-J4.
(d) No jumpers are placed on [Main]-J1, J2.
4. Connect a 12V DC power supply to [M3]-JP1.
5. Connect a 390 V DC power supply across [Main]-BS1, BS2.
6. Connect a load across [Main]-BS3, BS4.
CAUTION
This EVM is meant to be operated in a lab environment only and is not
considered by TI to be a finished end-product fit for general consumer use.
This EVM must be used only by qualified engineers and technicians familiar
with risks associated with handling high voltage electrical and mechanical
components, systems and subsystems.
This equipment operates at voltages and currents that can result in electrical
shock, fire hazard or personal injury if not properly handled or applied.
Equipment must be used with necessary caution and appropriate safeguards
employed to avoid personal injury or property damage.
It is your responsibility to confirm that the voltages and isolation requirements
are identified and understood, prior to energizing the board and or simulation.
When energized, the EVM or components connected to the EVM should not be
touched.
6
High-Voltage Half-Bridge LLC Resonant DC/DC Converter With Synchronous
SPRABS1 – February 2013
Rectification Hardware Kit
Copyright © 2013, Texas Instruments Incorporated