3
Protection
3.1
Short-Circuit Protection and Fault Reporting Circuitry
3.2
Fault Reporting
www.ti.com
Protection
This chapter describes the short-circuit protection and fault reporting circuitry of the TAS5142 device.
The TAS5142 is a self-protecting device that provides fault reporting (including high-temperature
protection and short-circuit protection). The TAS5142 is configured in back-end auto-recovery mode and
therefore resets automatically after all errors (M1 and M3 are set low, M2 is set high); see the TAS5142
Stereo Digital Amplifier Power Stage 
data sheet (
) for further explanation. This means that the
device will protect itself after an error condition and report the error through the SD error signal.
The OTW and SD outputs from the TAS5142 indicate fault conditions. See the TAS5142 Stereo Digital
Amplifier Power Stage 
data sheet (
for a description of these pins.
Table 3. TAS5142 Warning/Error Signal Decoding
OTW
SD
Device Condition
0
0
High-temperature error and/or high-current error
0
1
High-temperature warning
1
0
Undervoltage lockout or high-current error
1
1
Normal operation, no errors/warnings
The temperature warning signals at the TAS5142DDV6EVM2 board are wired-OR to one temperature
warning signal (OTW – pin 22 in control interface connector). Shutdown signals are wired-OR into one
shutdown signal (SD – pin 20 in control interface connector).
The shutdown signals, together with the temperature warning signal, give chip state information as
described in
. Device fault-reporting outputs are open-drain outputs.