Texas Instruments IC MCU 16B MSP430F2013TPW TSSOP-14 TID MSP430F2013TPW Datenbogen

Produktcode
MSP430F2013TPW
Seite von 93
MSP430F20x3
MSP430F20x2
MSP430F20x1
SLAS491I – AUGUST 2005 – REVISED DECEMBER 2012
10-Bit ADC, Linearity Parameters (MSP430F20x2)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
V
CC
MIN
TYP
MAX
UNIT
E
I
Integral linearity error
2.2 V, 3 V
±1
LSB
E
D
Differential linearity error
2.2 V, 3 V
±1
LSB
E
O
Offset error
Source impedance R
S
< 100
Ω
2.2 V, 3 V
±1
LSB
E
G
Gain error
2.2 V, 3 V
±1.1
±2
LSB
E
T
Total unadjusted error
2.2 V, 3 V
±2
±5
LSB
10-Bit ADC, Temperature Sensor and Built-In V
MID
(MSP430F20x2)
(1)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
V
CC
MIN
TYP
MAX
UNIT
2.2 V
40
120
Temperature sensor supply
REFON = 0, INCHx = 0Ah,
I
SENSOR
µA
current
(1)
T
A
= 25°C
3 V
60
160
TC
SENSOR
ADC10ON = 1, INCHx = 0Ah
(2)
2.2 V, 3 V
3.44
3.55
3.66 mV/°C
V
Offset,Sensor
Sensor offset voltage
ADC10ON = 1, INCHx = 0Ah
(2)
-100
100
mV
Temperature sensor voltage at
1265
1365
1465
T
A
= 105°C (T version only)
Temperature sensor voltage at
1195
1295
1395
T
A
= 85°C
V
SENSOR
Sensor output voltage
(3)
2.2 V, 3 V
mV
Temperature sensor voltage at
985
1085
1185
T
A
= 25°C
Temperature sensor voltage at
895
995
1095
T
A
= 0°C
Sample time required if
ADC10ON = 1, INCHx = 0Ah,
t
SENSOR(sample)
2.2 V, 3 V
30
µs
channel 10 is selected
(4)
Error of conversion result
1 LSB
2.2 V
N/A
Current into divider at
I
VMID
ADC10ON = 1, INCHx = 0Bh
µA
channel 11
(4)
3 V
N/A
2.2 V
1.06
1.1
1.14
ADC10ON = 1, INCHx = 0Bh,
V
MID
V
CC
divider at channel 11
V
V
MID
0.5 × V
CC
3 V
1.46
1.5
1.54
2.2 V
1400
Sample time required if
ADC10ON = 1, INCHx = 0Bh,
t
VMID(sample)
ns
channel 11 is selected
(5)
Error of conversion result
1 LSB
3 V
1220
(1)
The sensor current I
SENSOR
is consumed if (ADC10ON = 1 and REFON = 1), or (ADC10ON = 1 and INCH = 0Ah and sample signal is
high).When REFON = 1, I
SENSOR
is included in I
REF+
.When REFON = 0, I
SENSOR
applies during conversion of the temperature sensor
input (INCH = 0Ah).
(2)
The following formula can be used to calculate the temperature sensor output voltage:
V
Sensor,typ
= TC
Sensor
( 273 + T [°C] ) + V
Offset,sensor
[mV] or
V
Sensor,typ
= TC
Sensor
T [°C] + V
Sensor
(T
A
= 0°C) [mV]
(3)
Results based on characterization and/or production test, not TC
Sensor
or V
Offset,sensor
.
(4)
No additional current is needed. The V
MID
is used during sampling.
(5)
The on time, t
VMID(on)
, is included in the sampling time, t
VMID(sample)
; no additional on time is needed.
42
Copyright © 2005–2012, Texas Instruments Incorporated