Texas Instruments IC MCU 16B MSP430F2001TPW TSSOP-14 TID MSP430F2001TPW Datenbogen

Produktcode
MSP430F2001TPW
Seite von 93
MSP430F20x3
MSP430F20x2
MSP430F20x1
SLAS491I – AUGUST 2005 – REVISED DECEMBER 2012
Low-Power Mode Supply Currents (Into V
CC
) Excluding External Current
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
(1) (2)
PARAMETER
TEST CONDITIONS
T
A
V
CC
MIN
TYP
MAX
UNIT
f
MCLK
= 0 MHz,
2.2 V
65
80
f
SMCLK
= f
DCO
= 1 MHz,
f
ACLK
= 32,768 Hz,
Low-power mode 0
I
LPM0,1MHz
BCSCTL1 = CALBC1_1MHZ,
µA
(LPM0) current
(3)
3 V
85
100
DCOCTL = CALDCO_1MHZ,
CPUOFF = 1, SCG0 = 0,
SCG1 = 0, OSCOFF = 0
f
MCLK
= 0 MHz,
2.2 V
37
48
f
SMCLK
= f
DCO(0, 0)
100 kHz,
Low-power mode 0
f
ACLK
= 0 Hz,
I
LPM0,100kHz
µA
(LPM0) current
(3)
RSELx = 0, DCOx = 0,
3 V
41
52
CPUOFF = 1, SCG0 = 0,
SCG1 = 0, OSCOFF = 1
f
MCLK
= f
SMCLK
= 0 MHz, f
DCO
= 1
-40°C to 85°C
22
29
2.2 V
MHz,
105°C
31
f
ACLK
= 32,768 Hz,
Low-power mode 2
-40°C to 85°C
25
32
I
LPM2
BCSCTL1 = CALBC1_1MHZ,
µA
(LPM2) current
(4)
DCOCTL = CALDCO_1MHZ,
3 V
CPUOFF = 1, SCG0 = 0,
105°C
34
SCG1 = 1, OSCOFF = 0
-40°C
0.7
1.2
25°C
0.7
1
2.2 V
85°C
1.4
2.3
f
DCO
= f
MCLK
= f
SMCLK
= 0 MHz,
105°C
3
6
Low-power mode 3
f
ACLK
= 32,768 Hz,
I
LPM3,LFXT1
µA
(LPM3) current
(3)
CPUOFF = 1, SCG0 = 1,
-40°C
0.9
1.2
SCG1 = 1, OSCOFF = 0
25°C
0.9
1.2
3 V
85°C
1.6
2.8
105°C
3
7
-40°C
0.4
0.7
25°C
0.5
0.7
2.2 V
85°C
1
1.6
f
DCO
= f
MCLK
= f
SMCLK
= 0 MHz,
f
ACLK
from internal LF oscillator
105°C
2
5
Low-power mode 3
I
LPM3,VLO
(VLO),
µA
(LPM3) current
(4)
-40°C
0.5
0.9
CPUOFF = 1, SCG0 = 1,
SCG1 = 1, OSCOFF = 0
25°C
0.6
0.9
3 V
85°C
1.3
1.8
105°C
2.5
6
-40°C
0.1
0.5
f
DCO
= f
MCLK
= f
SMCLK
= 0 MHz,
25°C
0.1
0.5
Low-power mode 4
f
ACLK
= 0 Hz,
I
LPM4
2.2 V, 3 V
µA
(LPM4) current
(5)
CPUOFF = 1, SCG0 = 1,
85°C
0.8
1.5
SCG1 = 1, OSCOFF = 1
105°C
2
4
(1)
All inputs are tied to 0 V or to V
CC
. Outputs do not source or sink any current.
(2)
The currents are characterized with a Micro Crystal CC4V-T1A SMD crystal with a load capacitance of 9 pF.
(3)
Current for brownout and WDT clocked by SMCLK included.
(4)
Current for brownout and WDT clocked by ACLK included.
(5)
Current for brownout included.
Copyright © 2005–2012, Texas Instruments Incorporated
23