0
1
t d(BOR)
VCC
V(B_IT−)
Vhys(B_IT−)
V
CC(start)
MSP430F20x3
MSP430F20x2
MSP430F20x1
SLAS491I – AUGUST 2005 – REVISED DECEMBER 2012
POR and Brownout Reset (BOR)
(1) (2)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
V
CC
MIN
TYP
MAX
UNIT
0.7 ×
V
CC(start)
See
dV
CC
/dt
3 V/s
V
V
(B_IT-)
V
(B_IT-)
See
through
dV
CC
/dt
3 V/s
1.71
V
V
hys(B_IT-)
See
dV
CC
/dt
3 V/s
70
130
210
mV
t
d(BOR)
See
2000
µs
Pulse duration needed at RST/NMI pin to
2.2 V,
t
(reset)
2
µs
accept reset internally
3 V
(1)
The current consumption of the brownout module is already included in the I
CC
current consumption data. The voltage level V
(B_IT-)
+
V
hys(B_IT-)
is
1.8 V.
(2)
During power up, the CPU begins code execution following a period of t
d(BOR)
after V
CC
= V
(B_IT-)
+ V
hys(B_IT-)
. The default DCO settings
must not be changed until V
CC
V
CC(min)
, where V
CC(min)
is the minimum supply voltage for the desired operating frequency.
Figure 8. POR/Brownout Reset (BOR) vs Supply Voltage
Copyright © 2005–2012, Texas Instruments Incorporated
27