Flash Memory
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
V
CC
MIN
TYP
MAX
UNIT
V
CC (PGM/ERASE)
Program and erase supply voltage
2.2
3.6
V
f
FTG
Flash timing generator frequency
257
476
kHz
I
PGM
Supply current from V
CC
during program
2.2 V/3.6 V
3
5
mA
I
ERASE
Supply current from V
CC
during erase
2.2 V/3.6 V
3
7
mA
t
CPT
Cumulative program time
(1)
2.2 V/3.6 V
10
ms
t
CMErase
Cumulative mass erase time
2.2 V/3.6 V
20
ms
Program/erase endurance
10
4
10
5
cycles
t
Retention
Data retention duration
T
J
= 25
°
C
100
years
t
Word
Word or byte program time
See
(2)
30
t
FTG
t
Block, 0
Block program time for first byte or word
See
(2)
25
t
FTG
Block program time for each additional
t
Block, 1-63
See
(2)
18
t
FTG
byte or word
t
Block, End
Block program end-sequence wait time
See
(2)
6
t
FTG
t
Mass Erase
Mass erase time
See
(2)
10593
t
FTG
t
Seg Erase
Segment erase time
See
(2)
4819
t
FTG
(1)
The cumulative program time must not be exceeded when writing to a 64-byte flash block. This parameter applies to all programming
methods: individual word/byte write and block write modes.
(2)
These values are hardwired into the flash controller
'
s state machine (t
FTG
= 1/f
FTG
).
RAM
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
MAX
UNIT
V
(RAMh)
RAM retention supply voltage
(1)
CPU halted
1.6
V
(1)
This parameter defines the minimum supply voltage V
CC
when the data in RAM remains unchanged. No program execution should
happen during this supply voltage condition.
JTAG Interface
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
V
CC
MIN
TYP
MAX
UNIT
2.2 V
0
5
MHz
f
TCK
TCK input frequency
(1)
3 V
0
10
MHz
R
Internal
Internal pulldown resistance on TEST
2.2 V/3 V
25
60
90
k
Ω
(1)
f
TCK
may be restricted to meet the timing requirements of the module selected.
JTAG Fuse
(1)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
T
A
MIN
MAX
UNIT
V
CC(FB)
Supply voltage during fuse-blow condition
25
°
C
2.5
V
V
FB
Voltage level on TEST for fuse blow
25
°
C
6
7
V
I
FB
Supply current into TEST during fuse blow
25
°
C
100
mA
t
FB
Time to blow fuse
25
°
C
1
ms
(1)
Once the fuse is blown, no further access to the JTAG/Test and emulation features is possible, and the JTAG block is switched to