EVM Software Overview
5.2.5
Setting the Input Multiplexer
The input multiplexer (mux) of the PGA112 (or PGA113) device can be set by the Input Mux drop-down
menu shown in
. External test points VCAL/CH0 and CH1 can be selected in this menu, as well
as the various calibration inputs.
Figure 14. Input Mux Configuration
5.2.6
Setting Gain
Use the Gain drop-down menu shown in
to configure the PGA112 (or PGA113) device gain
value.
Figure 15. Setting the Gain