Insys GSM EASY 4.1 11-02-01-03-01.027 Benutzerhandbuch

Produktcode
11-02-01-03-01.027
Seite von 40
Function Descriptions 
INSYS GSM 4.2 easy 
18 
January 07
 
3.3.2  Setting an object instance 
Command:  
SET <Objectshortname><Instance>=<Value>[,CN:[ Callback]] 
Or: 
SET <Alias>=<Value>[,CN:[ Callback]] 
 
The object instance is set to the according value. 
If callback is desired, the reply will contain "SUCCESS” for a successful setting 
procedure or “NO SUCCESS” for a failed setting procedure. 
The specification of “CN:”  is optional. If the reply should be sent to another 
number than the sender number of the monitor command, an additional space 
character and the callback number must be entered after "CN:" . 
 
Valid objects for the easy 800/MFD: 
Object 
Object short name 
Valid values 
Digital registers 
0 or 1 
Analogue byte 
register 
MB 
0 to 255 
Analogue word 
register 
MW 
0 to 65535 
Analogue double 
word register 
MD -2147483648 
to 
2147483647 
 
 
Valid objects for the easy 500/700: 
Object 
Object short name 
Valid values 
Digital registers 
0 or 1 
Digital registers 
0 or 1 
 
Example 1: Setting the object instance M12 to 1: 
SET M12=1,CN:  
In this case, an SMS is sent to the sender number of the command, which sets the 
value of the object instance M12 to 1. 
 
Example 2: Setting the alias "Pump" with password "SECRET" and separate 
callback number "0123456789". 
SECRET,SET PUMP=123,CN: 0123456789 
In this case, the alias "PUMP" is linked to an object "analogue byte register", 
"analogue word register" or "analogue double word register". 
Note: 
Theoretically it is possible to set all other object instances, too. 
INSYS MICROELECTRONICS recommends paralleling the 
corresponding registers within the configuration program of the 
easy to avoid impact on the proper function of the easy objects.