Insys GSM Small 11-02-01-03-02.001 Benutzerhandbuch

Produktcode
11-02-01-03-02.001
Seite von 57
34 
6. Function Description 
When the INSYS GSM small is in normal mode during the alarm time, the following 
message appears: 
+CALA: Good morning 
 
When the INSYS GSM small is in power down mode during the alarm time, the RTC alarm 
mode is entered with the message: 
^SYSSTART ALARM MODE 
+CALA: Good morning 
 
After an alarm has occurred, the alarm time is set to “00/01/01,00:00:00“ ; the 
parameter <text> is maintained. 
6.4.3  Change of Status 
In the following, please find a brief overview of the possible changes to and from the 
various operating modes. 
 
The possibilities in sleep mode depend on the sleep mode settings with AT+CFUN  (see 
sleep modes). 
 
 Next 
 mode 
Current 
mode 
Normal Sleep  Power 
Down 
Power Down RTC 
Alarm 
Normal 
- - - 
AT+CFUN AT^SMSO 
- - - 
Sleep 
Reset via 
reset terminal 
RTS negative 
edge 
Non-
synchronized 
event code 
Incoming call 
AT command 
Incoming SMS 
RTC alarm 
AT+CFUN=1 
 
- - - 
AT^SMSO 
- - - 
Power Down: 
- Reset via reset 
terminal 
- - - 
- - -  
RTC-Alarm 
Power Down RTC 
Alarm 
- Reset via reset 
terminal 
- - -  
AT^SMSO 
- - - 
 
 
 
Version  1.00 / 09.04