Insys GSM Small 11-02-01-03-02.001 Benutzerhandbuch

Produktcode
11-02-01-03-02.001
Seite von 57
40 
7. Command Overview 
To ease readability of the further comments, <CR>  is always used as carriage return 
character. The standard responses are always OK or ERROR , regardless of the actually 
selected responses according to V.25. 
 
After the response to a command, a waiting period of at least 100 ms is recommended 
before the next command to enable the sending of more non-synchronous event codes, 
if necessary. 
 
For lining up standard AT commands please refer to the detailed command set of the 
GSM engine. 
 
7.2  Short Description AT commands 
The AT commands comprise the specification according to V.25ter, GSM 07.07 and GSM 
07.05. Only the most important AT commands with syntax and parameters are described 
in the following. A complete command reference of the Siemens TC35i is available from 
INSYS MICRO-ELECTRONICS (e-mail: insys@insys-tec.de). 
The applicability of single features may depend on the functionality of the selected GSM 
network. 
Syntax: 
<expressions>
 in angular brackets stand for parameters.  
 
[expressions]
 in square brackets stand for optional entries.
 
 
Default settings are set off in bold
7.2.1  AT Commands According To V.25ter 
+++ 
Change from data mode to command mode (online command mode).  1 second 
pause before and after the entry, no <CR>. 
ATA 
Call acceptance (see also ATS0 for automatic call acceptance) 
ATD[<n>] 
Dialing the phone number <n>
ATDL  
Last number re-dialing 
ATE<n> 
Set command echo:  
<n>
 0 
 Off 
 
1 on 
ATH 
Terminate existing connection  
ATI 
Output of product information of the GSM engine 
ATO 
Switch back from command mode to data mode 
 
 
Version  1.00 / 09.04