Operating the device
4.  Handling
4.1  The display 
Figure 3
4.1.1  Status tokens
The status tokens in the display indicate following:
CV - Voltage regulation active (only if output is „on“)
CC - Current regulation active (only if output is „on“)
Preset V/C - Set value display of voltage/current active
Preset OVP/OCP - Set value display of OVP/OCP active
OT - Overtemperature error
OCP - Overcurrent protection
OVP - Overvoltage protection
Remote - Remote control active (via USB)
Lock - Control panel lock active
4.1.2  Error indication
If an error like overvoltage, overcurrent or overtempera-
ture occurs it is displayed by the text „Error“ and a token 
(OT, OCP, OVP) and the output voltage is cut off. The text 
remains in the display until the user has acknowledged 
the error with the „On/Off“ button, which will also switch 
the output off. After an overtemperature error, the output 
voltage will return automatically and „Error“ will be cleared, 
unless the output has been switched off by the user. Other 
errors require the user to switch the output on again, in 
order to continue working with the device.
Other display elements are connected to certain operation 
modes and are explained in the following sections.
4.2  Pushbuttons
4.2.1  Pushbutton Preset 
This button is used to switch to preset mode and for acti-
vation/deactivation of the LOCK mode. 
Push Display
Mode
1x
 
Display of U/I set values
2x
 
Display  of  OVP/OCP  set 
3x
 
Activation/Deactivation  of  
4x
Display of U/I actual values
 
Set values are not stored when switching off the de-
vice and after the next start they are reset to 0% voltage 
and 100% current.
4.2.2  Pushbutton On/Off 
This pushbutton is used to manually switch the power out-
put on or off, as long as the device is not in remote control. 
The state of the output is indicated by
 or 
 in the display.
The pushbutton may be locked by the 
LOCK state. See 
above. Also see „5.5 Control panel lock (LOCK)“.
The button also acknowledges errors. See section 5.1.2 
for details.
4.3  Further control elements
Knobs Voltage 
 & Current 
These two rotary knobs have no stop and are used to adjust 
set values. Assignment:
•  Left knob - Voltage (U) or OVP, depending on mode
•  Right knob - Current (I) or OCP, depending on mode 
For details read below.
4.4   Adjusting set values
When adjusting the set values of voltage (U) and current (I), 
a rule becomes active where both set values adjust each 
other in order to not exceed the max. power of the device 
according to P
max
 = U
set
 * I
set
. It applies:
•  In 
Preset mode
If the output is off and the voltage set value is increased, 
the current set value will automatically decrease some-
time or if the current set value is increased, the voltage 
set value will automatically decrease sometime. For the 
output being on, it will behave like in normal operation.
•  During 
normal operation
a) If the output is on and 
constant voltage regulation 
is active (CV in the display), then the 
current set value 
can only be increased to a certain limit which is defined 
by the formula: maximum power = voltage set value * 
current set value (depending on the voltage set value)
b) If the output is on and 
constant current regulation 
(CC in the display) is active, then the 
voltage set value 
can only be increased to a certain limit which is defined 
by the formula: maximum power = voltage set value * 
current set value (depending in the current set value)
 The OVP threshold can be set to lower than the voltage 
set value! This can result in an immediate OV error.
 If the OCP value is identical to the current limitation 
and that limit is reached, the OCP will have priority and 
switch the output off.
Adjusting values manually can be done in 
fine or coarse 
steps.  Switching  is  done  by  pushing  the  corresponding 
knob.  In  normal  operation,  coarse  adjustment  mode  is 
default. If fine adjustment is selected and if no value has 
been changed for more than 10 seconds, the adjustment 
mode will automatically return to coarse. In Preset mode, 
the selected adjustment mode is held until Preset mode is 
aborted manually or automatically.