Replacing the light bulb 
Attention! Replace the defect bulb only when no voltage is applied (Disconnect mains plug!) and after the bulb as 
cooled down sufficiently.
 Observe that bulbs can become very hot.
 
Use only light bulbs with GX24q-3 socket and max. 3 x 32 W for this work lamp. Never use bulbs with a capacity higher 
than indicated. 
 
 
1. 
Switch off the lamp and disconnect the mains plug from the 230 V AC power supply. 
2. 
Remove the protective rubber ring (Fig. 1) and the cover (Fig. 2) 
Attention! Do not use sharp objects as tools to remove the protective rubber ring! They might damage the ring. 
3. 
Now remove the retaining spring of the bulb which needs to be replaced by pulling the lower end of the retaining 
spring apart (Fig. 5) and then remove it carefully. 
4. 
Remove the defect bulb (Fig. 3) carefully from the socket (Fig. 4) and replace it. 
5. 
Fix the light bulb by means of the retaining spring. 
6. 
Put the cover (Fig. 2) back on the lamp and re-attach the protective rubber ring (Fig. 1). 
During assembly, be sure to check that the protective rubber ring has a good and tight fit in order to prevent any water 
from entering. 
7. 
Now your work lamp is ready for use again. 
 
Attention! The work lamp must only be put into operation with duly closed housing
.
                                                                        
 
                     
 
 
                          Fig. 1                            Fig.2                             Fig. 3                            Fig. 4                                                                                      Fig. 5 
 
Maintenance and Cleaning  
Except for the replacement of light bulbs, the work lamp does not require any maintenance.  
 
Clean the outside of the device only with a soft cloth or brush. Never use aggressive cleaning agents or chemical solutions, 
since they may damage the housing or impair the function of the device.
 
 
Technical specifications 
Operating voltage:  
 
220 – 240 VAC/50 Hz 
 
Bulbs: 
 
3 x 32 W 
 
Socket: 
GX24q-3
 
Connection of sockets: 
 
max. 2700 W/12 A
 
Protection type: 
 
IP44
 
Protection class: 
 
I
 
Length of cable: 
 
5 m
 
Dimensions:  
 
200 x 280 mm
 
Weight:  
 
2,100 g
 
 
   
  
 
Environmental protection note 
At the end of its useful life, this product must not be disposed of together with normal household waste, but 
has to be dropped off at a collection centre for the recycling of electrical and electronic devices. 
 
This is indicated by the symbol on the product, on the instruction manual or on the packaging.  
The materials of which this product is made are recyclable pursuant to their labelling. With the reuse, the 
recycling of the materials or other forms of scrap usage you are making an important contribution to the 
protection of the environment. Please ask your local administration office for the appropriate disposal 
centre.
 
 
Technical specifications are subject to change. We assume no liability for typographical errors. V1_01/2012
 
IVT Innovative Versorgungs-Technik GmbH, Dienhof 14,  D-92242 Hirschau 