INSYS Modem 56k small INT 2.0/USB 1.0 
Functions 
June 06 
37 
5.10.2  Going off-hook on account of a telephone con-
nected in series 
If a telephone connected in series goes off-hook during an 
existing modem connection, the modem will immediately 
terminate the connection. 
The telephone is connected to the line and receives a dialing 
tone. 
In the registry S86, the value is set to 25. 
When the phone connection is terminated, the modem will 
not establish a new connection. 
 
Changing the loop voltage to detect the function – Off-hook 
on account of a telephone connected in series (U2) – can be 
set with the help of AT commands. 
 
 
 
Note: 
The detection starts immediately after the 
handset is picked up. To access the exchange, 
simple analogue phone systems often connect 
the modem per contact directly with the ex-
change, which results in a strong change or po-
larity reversal of the loop voltage.  For some 
analogue phone systems, this may result in an 
erroneous detection. Off-hook detection is 
therefore not recommended in connection with 
analogue phone systems.
 
U2 
Loop voltage prior 
to the connection. 
Time 
Voltage 
Loop voltage af-
ter a telephone 
connected in se-
ries goes off-
hook. 
ATS86=25
 
 
 
AT-TTE=U1, U2, U3