Cesys CEBO-STICK C028210 Datenbogen

Produktcode
C028210
Seite von 28
Trigger
After startup of CEBO-STICK, the multifunction IO-0 is configured as digital input signal. 
To use the trigger functionalities, output or input, the corresponding peripheral needs to 
be enabled first. This is done by software calls (API). While IO-0 is used as trigger 
input / output, digital IO functionalities or counter input are not available. With the help of 
the trigger output signal you can, for example, synchronize multiple CEBO-STICK 
devices. With the trigger as input signal, you can delay data acquisition until the 
occurrence of an external event.
Pin
Signal
Description
4
IO-0
Multifunction IO:
Default: Digital input / output 0
Alternate: Trigger input / output or counter input
5
GND
GND power terminal
Trigger
 input
In trigger input mode, you have to supply an external signal to terminal IO-0. You can 
use trigger events, for example, to delay the start of a buffered or continuous data 
acquisition until the occurrence of an external signal. In external timed data acquisition 
modes each trigger event trips the recording of a new frame, therefore the input signal 
defines the frame rate. CEBO-STICK can be configured for three different types of 
trigger input signals: rising edge, falling edge or alternating. 
Rising edge 
mode
In rising edge mode, every transition from low to high level on IO-0 is a trigger event.
Falling edge mode
In falling edge mode, every transition from high to low level on IO-0 is a trigger event.
CEBO-STICK Reference Manual
Cesys GmbH
v1.1
 ]
10/28
Figure 4: Trigger IO pin assignment