Cesys CEBO-STICK C028210 Datenbogen

Produktcode
C028210
Seite von 28
Software timed - one single frame
Capture and return one frame, which may consist of several input or output signals. 
Exact frame timing is not predictable, as it strongly depends on host system processing 
of requests targeting the USB interface. Therefore frame to frame timing might vary. 
With a typical system minimum time frames are between one and four microseconds, 
hence the maximum sample rate will be about 250 up to 1.000 frames per second.
Hardware timed - continuous frames
Capture and return an unlimited number of frames. The frame to frame timing is 
completely done by CEBO-STICK hardware and only stopped upon user request. If you 
need well defined sample rates at the highest data transfer levels use this mode.
The achievable maximum frame acquisition frequency is limited by the available data 
transfer rate between CEBO-STICK and the host system. With a fast host system total 
sample rates up to 188.000 Samples per second are possible.
Hardware timed - buffered frames
Frame data is captured to onboard memory of CEBO-STICK and stops automatically, 
when a given number of frames has been stored. The frame to frame timing is 
completely done by CEBO-STICK hardware. Use this mode, if you need a well defined 
sample rate at the highest data transfer levels, but your host system is not capable to 
sustain such high data rates. The number of acquisitions is limited by the buffer size of 
the CEBO-STICK. 
When external trigger is enabled, an edge on the TRG input is required to start 
capturing.
External timed - continuous/buffered frames
These acquisition modes are like the hardware-timed modes but with one difference: 
Timing is not done by CEBO-STICK hardware, but an adequate clock signal has to be 
provided on the trigger input. Edges on IO-0, configured as trigger input, start the 
acquisition of one frame. You can 
 to trip trigger events on 
falling, rising or both edges.
CEBO-STICK Reference Manual
Cesys GmbH
v1.1
 ]
15/28