Cesys CEBO-STICK C028210 Datenbogen

Produktcode
C028210
Seite von 28
5 Volt power output
Parameter
Min.
Typ.
Max.
Unit
Typical output voltage
4,75
5,0
5,25
Volts
Voltage drop due to cable impedance
0,150
Volts
Command and response times
Single value
Min.
Max.
Unit
Analog input
0,80
0,93
6,00
ms
Digital input
0,70
0,86
4,00
ms
Digital output
0,32
0,38
2,00
ms
Single frame
Min.
Max.
Unit
Analog inputs only
0,72
0,90
4,00
ms
Digital inputs only
0,72
0,90
4,00
ms
Analog and digital inputs
0,72
0,90
4,00
ms
Maximum number of frames for buffered mode
Frame setup
Maximum number of frames
1x analog input
4.095
4x analog input
1.023
Digital port
4.095
5x analog input + digital port + counter
585
Maximum sample rate - continuous DAQ
Frame setup
Typ.
Max.
Unit
1 analog input
100.000
Frames/s
2 analog inputs
50.000
76.000
Frames/s
3 analog inputs
33.500
59.000
Frames/s
4 analog inputs
24.000
49.000
Frames/s
Digital port
100.000
Frames/s
4 analog inputs + digital port
20.000
42.500
Frames/s
CEBO-STICK Reference Manual
Cesys GmbH
v1.1
 ]
24/28