Extech AN310 Anemometer AN310 Datenbogen

Produktcode
AN310
Seite von 12
AN310-EU-EN V1.2   1/13 
10
Specifications 
Air Velocity 
Ranges 
Resolution 
Accuracy 
m/s (meters per sec) 
0.2 – 30 m/s 
0.01 m/s 
± (1.5%rdg + 0.3 m/s) 
fpm (feet per minute) 
40 – 5900 fpm 
1 fpm 
± (1.5% rdg + 59 fpm) 
Relative Humidity 
Range 
Resolution 
Accuracy 
RH 
0.1%‐99.9%RH 
0.1 RH 
±
3%RH (10‐90%RH) 
±
5%RH (<10% or >90%)
 
Air Flow 
Ranges 
Resolution 
Area Range 
CMM (cubic meters/min) 
0‐99999 m
3
/min 
0.1 up to 9999.9
then 1.0 
0 to 99999cm
2
 
CFM (cubic ft/min) 
0‐99999 ft
3
/min 
0.1 up to 9999.9
then 1.0 
0 to 99999in
2
 
Temperature  
Ranges 
Resolution 
Accuracy 
o
C/
o
F 
Air and Wet Bulb: 
‐20 to 60
o
C (‐4 to 140
o
F) 
Dew Point: 
‐5 to 60
o
C (23 to 140
o
F) 
0.1
o
C/
o
F 
±0.6°C (‐20 to 50°C) 
±1.2°C (51 to 60°C) 
± 1.1°F (‐5 to 122°F) 
± 2.2°F (123 to 140°F) 
Circuit 
Custom LSI microprocessor 
Display 
Dual function 13 mm (0.5") 4‐digit LCD 
Sampling rate 
1 reading per second approx. 
Air velocity/flow sensor   Conventional angled vane arms with low‐friction ball bearing 
Sensors 
 
NTC‐type precision thermistors 
Automatic Power off 
Auto shut off after 20 minutes to preserve battery life (sleep mode) 
Operating Temperature  0°C to 50°C (32°F to 122°F) 
Storage Temperature 
‐10 to 50
o
C (14 to 122
o
F) 
Operating Humidity 
<80% RH 
Storage Humidity 
<90% RH 
Operating Altitude 
2000 meters (7000ft) maximum 
Battery Power 
Four (4) ‘AAA’ 1.5V batteries 
Battery Life 
> 40 hours 
Battery consumption 
8.3 mA DC (approx.) 
Weight 
725g (1.6 lbs.) including battery and probe 
Dimensions 
Main instrument: 269 x 106 x 51mm (10.6 x 4.2 x 2”) 
 
Optional Air Flow Adaptors: 
 
Round: 210mm (8.3”) Diameter 
 
Square: 346 x 346mm (13.6 x 13.6”)