Configuring the Library 
Configuring SNMP 
The library supports system monitoring via SNMP (Simple Network Management Protocol) and SNMP 
notifications. To enable SNMP, the remote management interface must be running. To enable SNMP 
notifications, you need to register the IP address of the notification recipient (host). 
The library ignores all SNMP SET operations, so external management applications cannot register 
themselves to receive SNMP traps from the library. The SNMP notification screen lets you manually 
register an external application. 
SNMP notification can only be set up by the Administrator from the remote management interface. 
The screen lists the existing IP address. The Port number is fixed to 162 UDP. 
The user needs to register the IP address of the notification recipient in the empty IP address field 
displayed on the screen. 
If you want to disable SNMP notifications enter 0.0.0.0 in the IP address field. Note that this disables 
notification only. The library will continue to process SNMP Get requests as long as the RMI is 
enabled. 
 
 Note 
You need to install the appropriate MIB for your FW version on the host on which 
the SNMP manager is running. 
 
The path to open the appropriate screen is: 
 
From the RMI, select Setup > Notification 
Configuring Notifications 
The library can be configured to automatically notify whenever an issue of a particular severity level 
occurs with one of its components. The notification can be received on the FPI, RMI or by e-mail. 
The notification received by e-mail provides a so called RAS ticket, a short problem description, and a 
possible cause which may be of help either to you or a customer service engineer. For more 
information about RAS tickets, please refer to 
Severity Level Threshold 
The library can be configured to filter out RAS tickets according to a Severity Level Threshold. There 
are three levels available: 
 
Low – An error has occurred in the library, but the library is not in danger of failing. (This setting 
enables all RAS tickets.) 
 
High - The library is not in immediate danger of failing, but current problems could lead to a failure 
in the future. (This setting enables RAS tickets with priority 1 and 2 only.) 
 
Urgent - The library has failed or is in immediate danger of failing. A resolution must be found 
immediately. (This setting enables RAS tickets with priority 1 only.) 
Configuring E-mail Notification 
Before you can configure e-mail notifications, you must configure the library’s e-mail account so that 
the library can send notifications to the designated recipient. E-mail notification can only be configured 
from the RMI. 
You need to complete the following steps to configure e-mail Event Notification: 
1.  Enable or disable the e-mail notification feature, as appropriate.