Troubleshooting Matrix 
The tables below describe different problem situations and suggested actions to try to resolve the 
problem. 
 
Table 7. Troubleshooting Matrix - Power with Solution 
Problem 
 
Solution 
Power 
Library does not power on 
Check the power cord connections and check that the power cords 
are connected in the correct AC-inlet. 
Make sure there is power to the outlet. Try another working outlet. 
Verify that the power supply is properly inserted into the bay. 
Check that the correct power switches are in the ON position. 
Replace the power cord. 
Make sure the fuses are not blown. Replace the fuse with a 
250V / 2A fast fuse if blown.  
Replace power supplies. 
Contact your service representative. 
The display is dead 
Check the power cord connections and check that the power cords 
are connected in the correct AC-inlet. 
Make sure there is power to the outlet. Try another working outlet. 
Verify that the power supply unit is properly inserted into the bay. 
Check that the correct power switches are in the ON position. 
Power cycle the library. If you use redundant power supplies, 
remember to turn both switches OFF. Verify that the fans start at 
power-on and that they calm down after a few seconds. 
Replace the power cord. 
Make sure the fuses are not blown. Replace the fuse with a 
250V / 2A fast fuse if blown. 
Replace power supplies. 
Contact your service representative. 
The front panel does not 
display information but the 
back light on the front panel is 
on 
Power cycle the library. If you use redundant power supplies, 
remember to turn both switches OFF. 
Verify that the fans start at power on and that they stop after a few 
seconds. 
Contact your service representative.