PEL-3000 Programming Manual 
128
 
Syntax 
:UTILity:LOAD {OFF|ON|LOAD|PROG|NSEQ|FSEQ} 
Query Syntax 
:UTILity:LOAD? 
Parameter 
OFF 
Turns Auto Load off. 
ON 
Turns Auto Load on. This 
will turn the load on 
automatically at start up.  
The type of load function 
that is automatically 
turned on is configured 
below. 
LOAD 
Configure the load to 
automatically turn on in 
CC, CR, CV or CP mode. 
PROG 
Configure the load to 
automatically turn on a 
program sequences. 
NSEQ 
Configure the load to 
automatically turn on a 
normal sequence. 
FSEQ 
Configure the load to 
automatically turn on a 
fast sequence. 
Return Parameter  <string> 
Load:On|Off, Load 
On:Load|Prog|NSeq|FSeq 
Example 
:UTILity:LOAD ON FSEQ 
Configures the unit to automatically turn fast 
sequences on at start up (with the load on). 
Query example 
:UTILity:LOAD? 
> Load:On, Load On:Prog 
The unit is configured to automatically turn Programs 
on at start up (with the load on). 
:UTILity:LOAD:MODE 
Set
Query
 
 
Description 
Sets or queries the Load Off (Mode) setting. This is 
equivalent to the settings in the 
Shift+UTILITY>Load menu.