Gw Instek PEL-3211 Electronic Load PEL-3211 Datenbogen

Produktcode
PEL-3211
Seite von 174
 
 
PEL-3000 Programming Manual 
162
 
-131 Invalid suffix 
The suffix does not follow the 
syntax described in IEEE 488.2 or 
the suffix is inappropriate for this 
device. 
-134 Suffix too long 
The suffix contained more than 12 
characters. 
-138 Suffix not allowed 
A suffix was encountered after a 
numeric element which does not 
allow suffixes. 
-140 Character data error 
This error is generated when 
parsing a character data element. 
-141 Invalid character data 
Either the character data element 
contains an invalid character or 
the particular element received is 
not valid for the header. 
-144 Character data too long 
The character data element 
contains more than twelve 
characters 
-148 Character data not allowed 
A legal character data element 
was encountered where 
prohibited by the device. 
-150 String data error 
This error is generated when 
parsing a string data element. 
-151 Invalid string data 
A string data element was 
expected, but was invalid for 
some reason. 
-158 String data not allowed 
A string data element was 
encountered but was not allowed 
by the device at this point in 
parsing. 
-160 Block data error 
This error is generated when 
parsing a block data element. 
-161 Invalid block data 
A block data element was 
expected, but was invalid for 
some reason.