29 
*OPC 
Set
Query
 
 
Description 
This command sets the OPC (Operation Command 
Bit) bit (bit 0) of the Standard Event Status Register 
after the instrument has completed all pending 
operations. The query will return the status of the 
OPC bit. 
Syntax 
*OPC 
Query Syntax 
*OPC? 
Return parameter  <NR1>  
 
  
  
 
Operation complete 
Query Example 
*OPC? 
>1 
Indicates that all pending operations are complete. 
*RCL 
Set
 
 
Description 
The Recall Instrument State command restores the 
instrument settings from a previously saved 
memory setting. 
Syntax 
*RCL <NR1> 
Parameter  
<NR1> 
 
1~256 
Memory number 1 to 256 
Example 
*RCL 20 
Recall setting memory 20. 
*RST 
Set
 
 
Description 
Resets the unit. This is command forces the 
ABORt, and *CLS 
Syntax 
*RST