Use the advanced configuration settings to configure settings other 
than those described in the basic configuration chapter. 
Soft Start Setting 
 
Description 
The soft start setting is used to limit the amount 
of input current at start-up or from when the 
Von Voltage threshold is tripped. 
 
The soft start setting only applies to CC, CR and 
CP mode.  
 
Input I
Time
Soft Start = ON
Input I
Time
Soft Start= OFF
Rise voltage
Rise current
Rise current
Rise voltage
 
Operation 
1.  Press 
Main
 > Configure[F5] > Other[F2] and 
set the Soft Start time.  
 
Range:  
OFF, 1~200ms