OPERATION 
81 
Display 
2.596
V
500.06
mA
1.2982
w
CV B Value
15.000
CV A Value
15.000
LOAD
RS232
A Value
Fine
03/Sep/2012
V
V
OCP Alarm
Please Press Enter
To Clear Alarm
OCP
OCP indicator
Alarm message 
when OCP is set 
to Load Off
Mode
CV
I Range
L 0.7A
V Range
L 15V
Response
Fast
Configure
 
OPP 
 
Description 
For OPP, the PEL-3000 can be configured to 
either limit the power or turn off the load. 
The OPP levels can be set to 10% higher than 
the rating power. 
Operation 
1.  Press 
Main
 > Configure[F5] > Protection[F1] 
and set the OPP Level and OPP Setting.  
 
Range:  
OPP Level: Rating power + 10% 
OPP Setting: LIMIT, Load Off 
Alarm 
 
When OPP Setting is configured to Load Off, a 
message will be displayed on the screen when 
OPP is tripped. The Enter key must be pressed 
to clear the alarm message.  
 
When configured to LIMIT, OPP will be 
displayed on the screen when the OPP is tripped 
and the power will be limited to the OPP Level 
setting.