Gw Instek PEL-3111 Electronic Load PEL-3111 Datenbogen
Produktcode
PEL-3111
PEL-3000 User Manual
94
Timing Diagram
for Single Step
for Single Step
Below is a timing diagram of a single step in a
program.
program.
On-Time
Off-Time
Step test time
Start of Step
End of Step
P/F End Test Time (fixed)
P/F Time
0.04s
0.06s
Short-Time
P/F Start Test Time (fixed)
Create a Program
Note
Before creating a program, the settings for each
step must first be created and saved to internal
memory (M001~M256). See the save recall chapter
for further details, page 119.
step must first be created and saved to internal
memory (M001~M256). See the save recall chapter
for further details, page 119.
Program Setting
Display Overview
Display Overview
Chain
Previous
Menu
LOAD
RS232
03/Sep/2012
Timing Edit for Program
On-Time:
Run:
Memory
0.1
Skip
M001
Short-Time:
P/F-Time:
Off-Time:
Off
Off
Off
STEP:
01
Program
Off
Recall
Default
Program
number
number
Step number in
selected program
selected program
Program
settings
settings
PROG:
01
Program
settings
settings
Operation
1. Press
FUNC
> Program[F1].
Note that Program[F1] is off by default.
2. Select PROG and select a program number to
edit.